Image from Google Jackets

Thermal efficiency enhancement on gas fired water heater using titanium heat exchanger for latent heat recovery

By: Contributor(s): Description: 6 pDDC classification:
  • CD I249 1 0013788
In: Summary: Transcripción del abstract original del autor: Thermal efficiency of gas fired water heater can be improved by latent heat recovery from the flue gas. However, it is usually accompanied with corrosion problem of heat exchanger caused by strong acid condensate. In this study, the heat transfer experiments of natural gas (13A) fired water heater has been performed using enhanced titanium tubes, which has excellent corrosion resistance as secondary heat exchanger for latent heat recovery. The parametric studies were conducted for mass flow rate and outlet temperature of hot water, respectively. Tube arrangements of heat exchanger including inline and staggered configurations were investigated. The thermal efficiency was evaluated based on the net calorific value at maximum rated output. As a result, the thermal efficiency of gas fired water heater with latent heat recovery heat exchanger was about 10% higher than that of the conventional instantaneous water heater.
Item type: Congresos (trabajos presentados)
Holdings
Current library Call number Status Barcode
Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 (Browse shelf(Opens below)) Not for loan 200025631

Disponible en CD en formato PDF

Transcripción del abstract original del autor: Thermal efficiency of gas fired water heater can be improved by latent heat recovery from the flue gas. However, it is usually accompanied with corrosion problem of heat exchanger caused by strong acid condensate. In this study, the heat transfer experiments of natural gas (13A) fired water heater has been performed using enhanced titanium tubes, which has excellent corrosion resistance as secondary heat exchanger for latent heat recovery. The parametric studies were conducted for mass flow rate and outlet temperature of hot water, respectively. Tube arrangements of heat exchanger including inline and staggered configurations were investigated. The thermal efficiency was evaluated based on the net calorific value at maximum rated output. As a result, the thermal efficiency of gas fired water heater with latent heat recovery heat exchanger was about 10% higher than that of the conventional instantaneous water heater.



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales