Effects of external radiation heat flux on combustion characteristics of pure and oil-impregnated transformer insulating paperboard (Record no. 193699)

MARC details
000 -LEADER
fixed length control field 02129nab a2200253 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2018 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Effects of external radiation heat flux on combustion characteristics of pure and oil-impregnated transformer insulating paperboard
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. sept. 2018
270 ## - FECHA DE CARGA
Fecha de carga 04/11/2020 ; 04/11/2020
300 ## - DESCRIPCION FISICA
Otra extensión 7 p. ; 362-368
520 ## - RESUMEN, ETC
Resumen The effects of external radiation heat flux on the combustion characteristics of pure transformer insulating paperboard (PTIP) and oil-impregnated transformer insulating paperboard (OITIP) were investigated experimentally. The experiments were conducted with the cone calorimeter using five external radiation heat fluxes that ranged from 25 to 80 kW/m2. The results showed that the ignition time decreased with the external radiation heat flux, and the ignition time of PTIP was much longer than that of OITIP. Both the PTIP and OITIP are thermal thick materials, and the critical radiation heat flux of the PTIP was larger than that of the OITIP. For the PTIP, the peak of the heat release rate (HRR) and toxic gas productions had no significant difference, while those of the OITIP increased with the external radiation heat flux. The HRR peak of the PTIP was larger than that of the OITIP with the external radiation heat fluxes of 25, 35, 50, and 65 kW/m2. When the radiation heat flux increased to 80 kW/m2, the HRR peak of the OITIP became higher. From the perspective of the CO production rate, the hazard of PTIP fires was more severe than that of OITIP fires under the external radiation heat fluxes of 25 and 35 kW/m2. The CO production rate of the PITP was lower than that of the OITP with the high external radiation heat fluxes of 50, 65 and 80 kW/m2
581 ## - ESTADO DE COLECCIÓN
Estado de colección 3
773 0# - CORRECCIÓN
Título Process safety progress
Partes relacionadas
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Zhang, Jiaqing
9 (RLIN) 54789
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Zhang, Bosi
9 (RLIN) 55540
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Fan, Minghao
9 (RLIN) 59822
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Wang, Liufang
9 (RLIN) 59823
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Ding, Goucheng
9 (RLIN) 59824
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Tian, Yu
9 (RLIN) 59825
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200066064   200066064 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales