Thermal Breakage of Tempered Glass Façade with Down-Flowing Water Film Under Different Heating Rates (Record no. 189675)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01965nab a2200253 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2016 xxu ing |
| 041 ## - IDIOMA | |
| Idioma | Inglés |
| 245 00 - TITULO | |
| Título | Thermal Breakage of Tempered Glass Façade with Down-Flowing Water Film Under Different Heating Rates |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | mar. 2016 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 27/07/2016 ; 26/07/2016 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 17 p. ; 563-580 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resúmen realizada por el autor: The objective of this work is to investigate the effect of the heating rate on the thermal breakage and fallout behavior of the tempered glass with down-flowing water film. The heating rate of the glass panes was controlled by changing the distance between the fire source and the glazing surface, which ranged from 0.6°C s-1 to 1.0°C s-1. N-heptane pool fire was adopted to heat up the glass panes and the fuel pan was positioned 500 or 600 mm away from the exposed glass surface. During the experiments the water film was initiated manually when the maximum glazing temperature reached different designed values. The results show that all the glazing panes kept their integrity when the fire source distance was 500 mm. In contrast, all the glass panes cracked and fell out the frame when the fire source distance was 600 mm except the one with the water film discharged at 200°C. The results illustrate that the heating rate plays a key role on the breakage of glass façades. Under the effect of water film or sprinkler system, glass panes are more likely to fail when exposed to a fire with smaller heat release rate or greater distance, rather than the opposite case. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 2 |
| 773 0# - CORRECCIÓN | |
| Título | Fire Technology |
| Partes relacionadas | 52 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Shao, Guangzheng |
| 9 (RLIN) | 55508 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Wang, Qingsong |
| 9 (RLIN) | 55507 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Zhao, Han |
| 9 (RLIN) | 55541 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Wang, Yu |
| 9 (RLIN) | 36839 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Sun, Jinhua |
| 9 (RLIN) | 55515 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | He, Linghui |
| 9 (RLIN) | 55542 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 06/03/2026 | 200061915 | 200061915 | 06/03/2026 | Artículo de Revista |