Fire Test of Profile Plank for Transformer Pit Fire Protection (Record no. 189660)

MARC details
000 -LEADER
fixed length control field 02012nab a2200205 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2016 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Fire Test of Profile Plank for Transformer Pit Fire Protection
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. mar. 2016
270 ## - FECHA DE CARGA
Fecha de carga 26/07/2016 ; 26/07/2016
300 ## - DESCRIPCION FISICA
Otra extensión 10 p. ; 309-319
520 ## - RESUMEN, ETC
Resumen Transcripción del resúmen realizada por el autor: In general it is recommended to fill a transformer pit with rock ballast to extinguish the fire if there is a leakage of burning transformer oil. There is a lack of technology-neutral performance requirements for the design of solutions for fire extinguishment in transformer pit fires. This hampers the introduction of alternatives to the traditional method of filling the pit with rocks. Therefore we have conducted quantitative tests where temperatures and concentrations of CO, CO2, and O2 were measured at different position in a transformer pit subjected to burning oil simulating an accidental rupture and leakage. The tests were conducted to investigate the extinguishing capacity of one specific alternative solution, i.e. a profile plank layer over the pit. Three tests were performed with 90°C and 140°C pre-heated transformer oil. In the second test, a 19 cm water bed was used to examine the impact of rain water in the pit. The result showed that the profile plank extinguished the flames in a few seconds and that the water level did not have any significant effect on the result. The measurements showed that the temperatures peaked at 600–800°C 50 cm above the profile plank in all tests but dropped to under 100°C in 14–16 s. Furthermore the O2-concentration dropped to 3–5 vol% below the plank, which contributed to the rapid extinction of the burning oil.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 2
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 52
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Lindström, Johan
9 (RLIN) 55494
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Försth, Michael
9 (RLIN) 55495
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200061900   200061900 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales