Fire Behaviour of Less-Combustible Dielectric Liquids in a Nuclear Facility (Record no. 189659)

MARC details
000 -LEADER
fixed length control field 02512nab a2200253 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2016 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Fire Behaviour of Less-Combustible Dielectric Liquids in a Nuclear Facility
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. mar. 2016
270 ## - FECHA DE CARGA
Fecha de carga 25/07/2016 ; 25/07/2016
300 ## - DESCRIPCION FISICA
Otra extensión 19 p. ; 289-308
520 ## - RESUMEN, ETC
Resumen Transcripción del resúmen realizada por el autor: Transformers, modulators and other high voltage electrical equipment are traditionally filled with mineral oil, which serves as a coolant and dielectric insulator. A rising trend is observed globally towards the adoption of less-combustible, bio-degradable transformer liquids at ever increasing voltages and power ratings. This paper presents a study of the fire behavior of five different dielectric transformer coolants: mineral oil, silicone liquid, synthetic ester, and two natural esters. Two types of tests were performed: comparative small-scale tests with two types of pans in the Cone Calorimeter (ISO 5660-1), and intermediate-scale pool fire experiments under the hood of an oxygen consumption calorimeter. The data obtained in this study are used in a fire engineering analysis of the evacuation and smoke removal from the 5900 m2 gallery in the planned European Spallation Source in Lund, Sweden. The comparative results indicate a wide range of fire properties for the tested liquids. The heat release rates calculated from the Cone Calorimeter experiments are reasonably consistent with tabulated values, except for the silicone liquid. The latter forms a crust on the liquid surface which significantly impedes combustion. Heat losses from the burning surface to cooler liquid below and pan boundaries have a significant effect on the burning behavior. These scale-dependent phenomena imply that great care should be taken in using small-scale burning data in a fire engineering analysis. Additional work is needed to gain a better understanding of the relation between small-scale tests and large-scale tests, and between the behavior of these liquids in pool fire experiments and that in real fires.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 2
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 52
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Hellebuyck, Denis H.
9 (RLIN) 55489
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Van Hees, Patrick
9 (RLIN) 50852
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Magnusson, Tommy
9 (RLIN) 55490
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Jörud, Fredrik
9 (RLIN) 55491
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Rosberg, Daniel
9 (RLIN) 55492
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Janssens, Marc L.
9 (RLIN) 55493
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200061899   200061899 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales