245 00 - TITULO
Título Fire Scenarios for Multi-storey Façades with Emphasis on Full-Scale Testing of Wooden Façades
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. nov. 2015
270 ## - FECHA DE CARGA
Fecha de carga 09/03/2016 ; 09/03/2016
300 ## - DESCRIPCION FISICA
Otra extensión 25 p. ; 1495-1510
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor: This paper briefly reviews the main fire scenarios for exterior façade claddings on multi-storey buildings, together with available full-scale test procedures and performance requirements in different countries. It is obvious that there is no international agreement or approach on how to evaluate the fire safety of façade claddings. Two series of full-scale fire tests of wooden façades, in accordance with the Swedish SP Fire 105 test, are presented: one series for different proportions of untreated wood (partial wood and structural fire protection with a fire shield above the window), and another series for fire-retardant-treated wood. The results are compared with data from the intermediate scale Single Burning Item test and the small scale cone calorimeter test. A main conclusion is that SP Fire 105 is a useful tool to evaluate the fire behaviour of façade claddings, but it should be complemented with more objective measurements. Claddings with partial wood and the use of a fire shield above the window fulfil the requirements. Wood claddings treated with fire retardants (FR) may fulfil the requirements, if the amount of FR is high enough. It is also essential to demonstrate the weather durability of the FR treatment. Good agreement has been found with the other test methods used. The need to use fire stops behind multi-storey façade claddings to avoid the spread of fire in cavities is underlined.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 51
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Ostman, Birgit
9 (RLIN) 55243
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Tsantaridis, Lazaros
9 (RLIN) 55244
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200061718   200061718 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales