Experimental Study of Combustible and Non-combustible Construction in a Natural Fire (Record no. 189480)

MARC details
000 -LEADER
fixed length control field 02125nab a2200229 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2015 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Experimental Study of Combustible and Non-combustible Construction in a Natural Fire
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. nov. 2015
270 ## - FECHA DE CARGA
Fecha de carga 09/03/2016 ; 09/03/2016
300 ## - DESCRIPCION FISICA
Otra extensión 27 p. ; 1447-1474
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor: With the adoption of performance-based fire design and the development of new engineered wood products, wood-based mid-rise and high-rise buildings are beginning to be constructed all around the globe. This trend has accelerated efforts to gain more understanding of the risks associated with combustible construction. To compare the differences between combustible and non-combustible construction, a series of full scale fire tests was conducted at Carleton University, the results of which are presented in this paper. These tests represented real bedroom fires with different room construction types: cross laminated timber (CLT) construction, light timber frame construction and light steel frame construction. Results showed that gypsum boards provided a better protection to CLT panels than to light frame walls. Compared with fires in the protected rooms, fire in the unprotected CLT room during the fully developed phase showed accelerated fire development and resulted in over 80% higher total heat release rate (THRR) but slightly lower room temperatures, and external burning contributed to about 64% of the THRR. It was also found that the light timber frame walls and light steel frame walls behaved very differently in the real fire. Furthermore, higher charring rates in both the unprotected CLT panels (1.0 mm/min) and wood studs (1.2 mm/min) were obtained in the real fire than those in the standard fire.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 51
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Li, Xiao
9 (RLIN) 55239
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Zhang, Xia
9 (RLIN) 55240
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Hadjisophocleous, George
9 (RLIN) 55241
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre McGregor, Cameron
9 (RLIN) 55242
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200061716   200061716 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales