Experimental Study of Combustible and Non-combustible Construction in a Natural Fire (Record no. 189480)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02125nab a2200229 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2015 xxu ing |
| 041 ## - IDIOMA | |
| Idioma | Inglés |
| 245 00 - TITULO | |
| Título | Experimental Study of Combustible and Non-combustible Construction in a Natural Fire |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | nov. 2015 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 09/03/2016 ; 09/03/2016 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 27 p. ; 1447-1474 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resumen del autor: With the adoption of performance-based fire design and the development of new engineered wood products, wood-based mid-rise and high-rise buildings are beginning to be constructed all around the globe. This trend has accelerated efforts to gain more understanding of the risks associated with combustible construction. To compare the differences between combustible and non-combustible construction, a series of full scale fire tests was conducted at Carleton University, the results of which are presented in this paper. These tests represented real bedroom fires with different room construction types: cross laminated timber (CLT) construction, light timber frame construction and light steel frame construction. Results showed that gypsum boards provided a better protection to CLT panels than to light frame walls. Compared with fires in the protected rooms, fire in the unprotected CLT room during the fully developed phase showed accelerated fire development and resulted in over 80% higher total heat release rate (THRR) but slightly lower room temperatures, and external burning contributed to about 64% of the THRR. It was also found that the light timber frame walls and light steel frame walls behaved very differently in the real fire. Furthermore, higher charring rates in both the unprotected CLT panels (1.0 mm/min) and wood studs (1.2 mm/min) were obtained in the real fire than those in the standard fire. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 6 |
| 773 0# - CORRECCIÓN | |
| Título | Fire Technology |
| Partes relacionadas | 51 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Li, Xiao |
| 9 (RLIN) | 55239 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Zhang, Xia |
| 9 (RLIN) | 55240 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Hadjisophocleous, George |
| 9 (RLIN) | 55241 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | McGregor, Cameron |
| 9 (RLIN) | 55242 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 06/03/2026 | 200061716 | 200061716 | 06/03/2026 | Artículo de Revista |