Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions (Record no. 189474)

MARC details
000 -LEADER
fixed length control field 02499nab a2200241 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2015 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. nov. 2015
270 ## - FECHA DE CARGA
Fecha de carga 03/03/2016 ; 03/03/2016
300 ## - DESCRIPCION FISICA
Otra extensión 29 p. ; 1341-1370
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor: Cross-laminated timber (CLT) is increasingly being used in medium-rise timber buildings for a number of reasons, such as rapidity of construction, cost effectiveness and robustness. Like for other building materials, verification of the load-bearing performance in fire conditions is an important issue. Experimental fire tests have been performed on loaded CLT wall elements at research institutes in Sweden and Italy. In total, three large-scale and four medium-scale tests have been carried out. The aim was to gain information about initially protected and unprotected elements, to be used for classification and also for validation of calculation models. In the test series, reference tests at normal temperature were included to obtain information (e.g. stiffness, strength) about the material tested in fire conditions. In addition, model-scale fire tests were performed to investigate the loss in stiffness resulting from fire exposure and the effect of different protection types. Loaded fire tests varied in the range of 41.8 min to 120 min, depending on the CLT structure, the level of load, and the type of protection. Data on temperature within specimens and residual cross-sections were collected. Charring rates evaluated from experimental results were comparable with values proposed by Eurocode for the design of timber structures. Conservative solutions were obtained by using simplified design methods and comparing their results to test results and results of advanced modelling. It was shown that the load-bearing performance of CLT may show abrupt changes due to its layered structure. It is strongly recommended that a minimum residual depth depending on the CLT structure should be required in order to ensure robust building products.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 51
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Schmid, Joachim
9 (RLIN) 55219
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Menis, Agnese
9 (RLIN) 55226
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Fragiacomo, Massimo
9 (RLIN) 55222
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Clemente, Isaia
9 (RLIN) 55227
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Bochicchio, Giovanna
9 (RLIN) 55228
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200061710   200061710 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales