Technical Assessment of Isothermal and Non-Isothermal Modelings of Natural Gas Pipeline Operational Conditions (Record no. 187695)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02109nab a2200205 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2012 xxu ing |
| 041 ## - IDIOMA | |
| Idioma | Inglés |
| 245 00 - TITULO | |
| Título | Technical Assessment of Isothermal and Non-Isothermal Modelings of Natural Gas Pipeline Operational Conditions |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | mayo/jun. 2012 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 15/05/2013 ; 15/05/2013 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 14 p. ; 435-449 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Traducción del resúmen del autor: Modeling of equipment in a gas pipeline was performed here by deriving a new form of conservation equation set for compressible flow. Then a section of the third Iranian gas transmission pipeline (Nourabad-Pataveh-Dorahan, N-P-D) was investigated by isothermal (IT) and non-isothermal (NIT) modeling approaches taking into account the effects of ground temperature. In the first part, the steady state operation of the N-P-D pipeline including a compressor station at Pataveh was studied. For the known values of natural gas mass flow rate, and inlet/outlet gas pressures at Nourabad/Dorahan points, the IT and NIT modelings showed about 33.7%, 16.6% and 23% maximum difference percent points for the compressors head, compressors rotational speed and fuel consumption rates respectively. In the second part, the unsteady operation of the N-P-D pipeline due to the shutdown of a compressor at Pataveh Compressor Station (PCS) was studied. The results confirmed that at lower ground temperatures (0 and 20°C), the remaining compressors could compensate the loss of one compressor. However, at higher ground temperatures (40 and 50°C), the compressors had to run faster than the highest permissible speed to be able to deliver a certain mass flow rate without reducing the required pipeline pressure. In all above studied cases, the computing time for the non-isothermal modeling was about three times longer than that for the isothermal one. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 3 |
| 773 0# - CORRECCIÓN | |
| Título | Oil and Gas Science and Technology |
| Partes relacionadas | 67 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Sanaye, S. |
| 9 (RLIN) | 53190 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Mahmoudimehr, J. |
| 9 (RLIN) | 53191 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 06/03/2026 | 200059837 | 200059837 | 06/03/2026 | Artículo de Revista |



