Experimental and Analytical Investigation of the Cool-Down Behavior of an Insulated Pipe Assembly Under Subsea Conditions (Record no. 187549)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02065nab a2200217 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2012 xxu ing |
| 041 ## - IDIOMA | |
| Idioma | Inglés |
| 245 00 - TITULO | |
| Título | Experimental and Analytical Investigation of the Cool-Down Behavior of an Insulated Pipe Assembly Under Subsea Conditions |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | jun. 2012 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 25/01/2013 ; 25/01/2013 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 14 p. ; 602-616 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resumen del autor: An experimental investigation was conducted to determine the cool-down behavior of an insulated pipe assembly under subsea conditions, and an analytical model was developed to predict the cool down of the assembly. The insulated pipe assembly consisted of a straight pipe attached to a production tee and a production elbow, and this was coated with 3 in. of thermal insulation. The pipe assembly was tested in a chamber that can simulate subsea conditions (low temperature, high pressure). The analytical model was the solution to a 1D transient heat-conduction problem of a three-layer solid cylinder. The analytical model was first verified with the use of available commercial software, and then validated against experimental data. Results showed a root-mean-square deviation (RMSD) of less than 3.8°F between the analytical model and the experimental data at the location with a geometry similar to that for which the analytical model was developed. It was found that the h values calculated from experimental data were significantly smaller than the ones calculated from empirical correlations. However, this variation resulted only in a slight difference in the cool-down temperatures. From the validation of the analytical model, it was concluded that this model can predict cool-down temperatures as a function of time in insulated pipes during shut-in operations. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 2 |
| 773 0# - CORRECCIÓN | |
| Título | SPE Journal |
| Partes relacionadas | 17 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Rivas-Cardona, A. |
| 9 (RLIN) | 52940 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Marotta, E. |
| 9 (RLIN) | 52941 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Whitsitt, E. |
| 9 (RLIN) | 52942 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 06/03/2026 | 200059672 | 200059672 | 06/03/2026 | Artículo de Revista |



