Experimental and Analytical Investigation of the Cool-Down Behavior of an Insulated Pipe Assembly Under Subsea Conditions (Record no. 187549)

MARC details
000 -LEADER
fixed length control field 02065nab a2200217 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2012 xxu ing
041 ## - IDIOMA
Idioma Inglés
245 00 - TITULO
Título Experimental and Analytical Investigation of the Cool-Down Behavior of an Insulated Pipe Assembly Under Subsea Conditions
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. jun. 2012
270 ## - FECHA DE CARGA
Fecha de carga 25/01/2013 ; 25/01/2013
300 ## - DESCRIPCION FISICA
Otra extensión 14 p. ; 602-616
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor: An experimental investigation was conducted to determine the cool-down behavior of an insulated pipe assembly under subsea conditions, and an analytical model was developed to predict the cool down of the assembly. The insulated pipe assembly consisted of a straight pipe attached to a production tee and a production elbow, and this was coated with 3 in. of thermal insulation. The pipe assembly was tested in a chamber that can simulate subsea conditions (low temperature, high pressure). The analytical model was the solution to a 1D transient heat-conduction problem of a three-layer solid cylinder. The analytical model was first verified with the use of available commercial software, and then validated against experimental data. Results showed a root-mean-square deviation (RMSD) of less than 3.8°F between the analytical model and the experimental data at the location with a geometry similar to that for which the analytical model was developed. It was found that the h values calculated from experimental data were significantly smaller than the ones calculated from empirical correlations. However, this variation resulted only in a slight difference in the cool-down temperatures. From the validation of the analytical model, it was concluded that this model can predict cool-down temperatures as a function of time in insulated pipes during shut-in operations.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 2
773 0# - CORRECCIÓN
Título SPE Journal
Partes relacionadas 17
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Rivas-Cardona, A.
9 (RLIN) 52940
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Marotta, E.
9 (RLIN) 52941
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Whitsitt, E.
9 (RLIN) 52942
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200059672   200059672 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales