Galvanic corrosion and inhibition of GW103 and AZ91D mg alloys coupled to an al alloy in an ethylene glycol solution at ambient and elevated temperatures (Record no. 187298)

MARC details
000 -LEADER
fixed length control field 01892nab a2200181 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2012 xxu
245 00 - TITULO
Título Galvanic corrosion and inhibition of GW103 and AZ91D mg alloys coupled to an al alloy in an ethylene glycol solution at ambient and elevated temperatures
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. jun. 2012
270 ## - FECHA DE CARGA
Fecha de carga 06/09/2012 ; 06/09/2012
300 ## - DESCRIPCION FISICA
Otra extensión 14 p. ; 475-488
520 ## - RESUMEN, ETC
Resumen The galvanic corrosion of GW103 and AZ91D coupled to an Al alloy (Al 7005 [UNS A97005]) in an ethylene glycol (EG [C2H6O2]) solution at ambient (25°C) and elevated temperatures (90°C) was investigated using open-circuit potential (OCP), coupling potential (CP), galvanic current density, potentiodynamic polarization curve, and electrochemical impedance spectroscopy (EIS). Moreover, weight-loss measurement and scanning electron microscopy (SEM) also were used to investigate the galvanic corrosion damage of the coupled Mg alloys. The galvanic corrosion behaviors of the couples were compared in the EG solution before and after a combination of inorganic inhibitor sodium phosphate (Na3PO4) and organic inhibitor sodium dodecylbenzenesulfonate (C18H29NaO3S) was added to the solution. It was found that both the general corrosion and galvanic corrosion of the Mg alloys were mitigated by the organic-inorganic inhibitor package. The most interesting finding was that the anode and cathode of the Mg alloy-Al alloy couples were reversed by adding inorganic and organic inhibitors into the blank EG solution. The anode-cathode reversal can be attributed to the OCP changes of the anode and cathode after inhibitor addition. The measured galvanic behavior was in good agreement with the mixed-potential theory predictions.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Corrosion
Partes relacionadas 68
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Huang, D.
9 (RLIN) 52635
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 06/03/2026 200059409   200059409 06/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales