Hybrid solution and pump-storage optimization in water supply system efficiency: A case study (Record no. 183034)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01923nab a2200193 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2008 xxu |
| 245 00 - TITULO | |
| Título | Hybrid solution and pump-storage optimization in water supply system efficiency: A case study |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | nov. 2008 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 23/06/2011 ; 23/06/2011 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 7 p. ; 4142-4148 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resumen del autor. Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. www.un.org, accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity tariff, for a pumped storage system with water consumption and inlet discharge. Wind turbines are introduced in the system. The rules obtained as output of the optimization process are subsequently introduced in a hydraulic simulator, in order to verify the system behaviour. A comparison with the normal water supply operating mode is done and the energy cost savings with this hybrid solution are calculated. Keywords: Pump-storage; Energy efficiency; Water supply systems |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 11 |
| 773 0# - CORRECCIÓN | |
| Título | Energy Policy |
| Partes relacionadas | 36 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Vieira, F. |
| 9 (RLIN) | 50391 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Ramos, H.M. |
| 9 (RLIN) | 50392 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 05/03/2026 | 200055081 | 200055081 | 05/03/2026 | Artículo de Revista |