High-temperature electrochemical sensor for online corrosion monitoring (Record no. 176895)

MARC details
000 -LEADER
fixed length control field 02231nab a2200193 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2010 xxu
245 00 - TITULO
Título High-temperature electrochemical sensor for online corrosion monitoring
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. sep. 2010
270 ## - FECHA DE CARGA
Fecha de carga 13/09/2010 ; 13/09/2010
300 ## - DESCRIPCION FISICA
Otra extensión 8 p. ; 095002
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. Electrochemical sensors incorporating diamond-like carbon (DLC)-coated electrodes are effective tools for online, real-time corrosion monitoring at high temperatures. A vacuum-based chemical vapor deposition process was used to deposit a DLC thinfilm coating on the surface of the sensing electrodes. The chemical inertness of the DLC coating on the sensing electrodes produced a crevice-free electrode that can be used at temperatures above 100°C. In this paper, we present the coating deposition process for sensor electrodes and fabrication of coupled multielectrode array sensors (CMAS) for high-temperature, high-pressure applications. Probes were fabricated using uncoated and DLC-coated Alloy 22 (Ni-22Cr-13Mo-3Fe-3W [UNS N06022]) and titanium Grade 7 (Ti-0.2Pd [UNS R52400]) electrodes. The Alloy 22 probes were tested in high-temperature, high-pressure conditions in a pH 10 caustic solution. The measured nonuniform corrosion rate using the Alloy 22 probe with the DLC-coated electrodes was approximately 2 µm/y. The titanium Grade 7 probes were tested in a dilute sodium chloride (NaCl) solution saturated with hydrogen sulfide-car-bon dioxide (H2S-CO2) at high pressures in the temperature range from 39°C to 81°C and in a saturated solution containing sodium chloride-sodium nitrate-potassium nitrate (NaCl-NaNO3-KNO3) at 150°C. The stabilized localized corrosion rates for probes with or without the DLC coating were less than 1 µm/y in the H2S-CO2 environment, and less than 0.03 µm/y in the NaCl-NaNO3-KNO3 salt mixture at 150°C. The test results indicate that titanium Grade 7 is not subject to crevice corrosion under the testing conditions.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 9
773 0# - CORRECCIÓN
Título Corrosion
Partes relacionadas 66
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Chiang, K.T.
9 (RLIN) 46836
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Yang, L.
9 (RLIN) 39177
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200048830   200048830 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales