Photoluminescent stairway installation for evacuation in office buildings (Record no. 176315)

MARC details
000 -LEADER
fixed length control field 02159nab a2200193 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2010 xxu
245 00 - TITULO
Título Photoluminescent stairway installation for evacuation in office buildings
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. jul. 2010
270 ## - FECHA DE CARGA
Fecha de carga 26/08/2010 ; 25/08/2010
300 ## - DESCRIPCION FISICA
Otra extensión 25 p. ; 471-495
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. Two experiments were conducted to assess the effectiveness of photoluminescent material (PLM) in support of occupant evacuation in office buildings. The first study completed in 1999 was designed to assess the potential use of PLM as a safety communication system to support office occupant evacuation. The study measured the occupant premovement time, movement time and evacuation speed in four stairways with different lighting and PLM installations. The positive outcome of the first study regarding a comparable speed of movement in the different stairways used and the conclusive feedback from the evacuees regarding the PLM wayguidance system led to a second study. The second study, completed in 2008, compared 3 stairway installations of PLM markings and a stairway with emergency lighting, which acted as a reference stairway. Results show comparable speed of movement under severe crowd conditions for the 4 stairways studied. Overall, two-thirds of the respondents felt comfortable going down the stairways with PLM markings particularly in the 2 stairways where the marking was installed across each step. The stairway, which had only emergency lighting, and the stairway with L-shaped markers at the edge of each step were less appreciated by the occupants. Occupants commented that the landings and mid-landings were difficult to identify in all the stairways, which suggest that additional marking should be provided in these areas. The findings of these two studies led to the development of a best practice Guide for installation of PLM marking in exit stairways.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 3
773 0# - CORRECCIÓN
Título Fire Technology
Partes relacionadas 46
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Proulx, Guylène
9 (RLIN) 46621
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Bénichou, Noureddine
9 (RLIN) 46622
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200048245   200048245 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales