Flow-field deflection within a cold small-scale model for a down-fired 300 MWe utility boiler at asymmetric staged-air distribution (Record no. 174374)

MARC details
000 -LEADER
fixed length control field 02164nab a2200205 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2011 xxu
245 00 - TITULO
Título Flow-field deflection within a cold small-scale model for a down-fired 300 MWe utility boiler at asymmetric staged-air distribution
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. ene./feb. 2011
270 ## - FECHA DE CARGA
Fecha de carga 01/04/2011 ; 01/04/2011
300 ## - DESCRIPCION FISICA
Otra extensión 11 p. ; 86-96
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. Deflected flow fields and large combustion differences between zones near front and rear walls have been found in Mitsui Babcock Energy Limited (MBEL) down-fired pulverized-coal boilers under a symmetric air distribution. To eliminate or mitigate the flow-field deflection and achieve relatively symmetric combustion in these boilers, the distribution of the staged air between the front and rear walls was adjusted to construct an asymmetric staged-air distribution. Cold airflow experiments over a wide range of asymmetric staged-air distributions [viz., differences in the ratio of staged-air mass flux between the front and rear walls (Rd) of -50, -25, 0, 13, 25, and 50%] were conducted within a small-scale furnace of a MBEL down-fired pulverized-coal 300 MWe utility boiler. At settings of Rd = -50, -25, 0, and 13%, there was a deflected flow field in the lower furnace, and this airflow was directed upward later near the front wall than near the rear wall. With Rd increasing from -50 to 13%, the flow-field deflection weakened. For settings of Rd = 25 and 50%, there was another flow-field deflection, with the downward airflow reversing direction earlier near the front wall than near the rear wall. With an increase in Rd from 25 to 50%, the flow-field deflection became more pronounced. To establish a flow field along with an appropriate airflow reach for more economical operation, an optimal setting of Rd = 13% was found for the staged-air distribution between the front and rear walls.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 1
773 0# - CORRECCIÓN
Título Energy & fuels
Partes relacionadas 25
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Li, Zhengqi
9 (RLIN) 38132
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Kuang, Min
9 (RLIN) 44995
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Yang, Pengfei
9 (RLIN) 44996
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200052391   200052391 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales