Flow-field deflection within a cold small-scale model for a down-fired 300 MWe utility boiler at asymmetric staged-air distribution (Record no. 174374)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02164nab a2200205 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2011 xxu |
| 245 00 - TITULO | |
| Título | Flow-field deflection within a cold small-scale model for a down-fired 300 MWe utility boiler at asymmetric staged-air distribution |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | ene./feb. 2011 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 01/04/2011 ; 01/04/2011 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 11 p. ; 86-96 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resumen del autor. Deflected flow fields and large combustion differences between zones near front and rear walls have been found in Mitsui Babcock Energy Limited (MBEL) down-fired pulverized-coal boilers under a symmetric air distribution. To eliminate or mitigate the flow-field deflection and achieve relatively symmetric combustion in these boilers, the distribution of the staged air between the front and rear walls was adjusted to construct an asymmetric staged-air distribution. Cold airflow experiments over a wide range of asymmetric staged-air distributions [viz., differences in the ratio of staged-air mass flux between the front and rear walls (Rd) of -50, -25, 0, 13, 25, and 50%] were conducted within a small-scale furnace of a MBEL down-fired pulverized-coal 300 MWe utility boiler. At settings of Rd = -50, -25, 0, and 13%, there was a deflected flow field in the lower furnace, and this airflow was directed upward later near the front wall than near the rear wall. With Rd increasing from -50 to 13%, the flow-field deflection weakened. For settings of Rd = 25 and 50%, there was another flow-field deflection, with the downward airflow reversing direction earlier near the front wall than near the rear wall. With an increase in Rd from 25 to 50%, the flow-field deflection became more pronounced. To establish a flow field along with an appropriate airflow reach for more economical operation, an optimal setting of Rd = 13% was found for the staged-air distribution between the front and rear walls. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 1 |
| 773 0# - CORRECCIÓN | |
| Título | Energy & fuels |
| Partes relacionadas | 25 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Li, Zhengqi |
| 9 (RLIN) | 38132 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Kuang, Min |
| 9 (RLIN) | 44995 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Yang, Pengfei |
| 9 (RLIN) | 44996 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 05/03/2026 | 200052391 | 200052391 | 05/03/2026 | Artículo de Revista |



