Investigation of Alternating Current Corrosion of Cathodically Protected Pipelines: Development of a Detection Method, Mitigation Measures, and a Model for the Mechanism (Record no. 171809)

MARC details
000 -LEADER
fixed length control field 02202nab a2200193 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2009 xxu
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Büchler, M.
9 (RLIN) 26743
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Schoneich, H.G.
9 (RLIN) 27036
245 00 - TITULO
Título Investigation of Alternating Current Corrosion of Cathodically Protected Pipelines: Development of a Detection Method, Mitigation Measures, and a Model for the Mechanism
260 ## - PUBLICACION, DISTRIBUCION, ETC
Fecha de publicación, distribución, etc. sep. 2009
270 ## - FECHA DE CARGA
Fecha de carga 07/07/2010 ; 06/07/2010
300 ## - DESCRIPCION FISICA
Otra extensión 9 p. ; 578-586
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. Investigations performed in recent years regarding alternating current (AC) corrosion on cathodically protected pipelines are reported and summarized. A model for the corrosion mechanism is shown and the formation of a rust layer is experimentally demonstrated. The use of the coulometric oxidation for detecting the degree of AC corrosion on coupons by oxidizing the Fe(II) in the rust layer is introduced and experimental results from field investigations are presented. The effect of the cathodic protection level on the corrosion rate is shown. In order to obtain data for optimizing the cathodic protection parameters, the corrosion rate was investigated at various on-potentials and interfering AC voltages. Based on the obtained results it was possible to demonstrate that the corrosion rate can significantly be decreased if the off-potential is more negative than -0.85 V vs. copper/copper sulfate (Cu/CuSO4) electrode (CSE) and the on-potential is in the range of -1.2 VCSE. Moreover, it was possible to demonstrate that the high AC corrosion rate on coupons can readily be decreased if the cathodic protection level is adjusted. To obtain an understanding of the processes involved and to clarify the influence of alkalinity on the corrosion rate, the effect of cathodic current density on the pH value on the metal's surface of coupons were analyzed with a new in situ pH measurement technique. The effects of pH, spread resistance, and electrochemical reduction are discussed with respect to the experimentally observed corrosion rate.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 9
773 0# - CORRECCIÓN
Título Corrosion
Partes relacionadas 65
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200046682   200046682 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales