Feasibility of microwave-induced combustion for digestion of crude oil vacuum distillation residue for chlorine determination (Record no. 170846)

MARC details
000 -LEADER
fixed length control field 02203nab a2200205 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2009 xxu
245 00 - TITULO
Título Feasibility of microwave-induced combustion for digestion of crude oil vacuum distillation residue for chlorine determination
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. nov./dic. 2009
270 ## - FECHA DE CARGA
Fecha de carga 09/06/2010 ; 09/06/2010
300 ## - DESCRIPCION FISICA
Otra extensión 5 p. ; 6015-6019
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. The microwave-induced combustion (MIC) method was applied for digestion of crude oil vacuum distillation residue for further chlorine determination. Ignition was performed by microwave radiation using a microwave oven designed for conventional pressurized wet digestion. Combustion was carried out using 20 bar of oxygen and NH4NO3 as the igniter. Water or H2O2, Na2CO3, and (NH4)2CO3 solutions were investigated for analyte absorption as well as the necessity of a reflux step. Digests were suitable to be analyzed by inductively coupled plasma optical emission spectrometry and ion chromatography. Accuracy was evaluated using spiked samples and certified reference materials of coal (BCR 181) and fuel oil (NIST 1634c). Recoveries for Cl were in the range of 98.4-100.2% for all investigated solutions using the reflux step. The agreement with certified values was better than 95% using 25 mmol L-1 (NH4)2CO3 as the absorbing solution and reflux step. Poor recoveries for Cl were observed using microwave-assisted wet digestion and water extraction procedures. Residual carbon content for MIC was below 1%, whereas it was about 20% using microwave-assisted wet digestion. Using MIC, up to 400 mg of sample could be decomposed and digestion was complete in less time (5 min for combustion and 20 min for cooling) in comparison to other conventional procedures (more than 1 h). Up to eight samples could be digested simultaneously, making the proposed procedure suitable for further routine Cl determination in oil refineries.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Energy & fuels
Partes relacionadas 23
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Pereira, Juliana S.F.
9 (RLIN) 42399
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Mello, Paola A.
9 (RLIN) 42400
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Duarte, Fábio A.
9 (RLIN) 42401
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200045700   200045700 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales