Isolation of size exclusion chromatography elution-fractions of coal and petroleum-derived samples and analysis by laser desorption mass spectrometry (Record no. 170845)

MARC details
000 -LEADER
fixed length control field 02097nab a2200205 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2009 xxu
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Morgan, Trevor J.
9 (RLIN) 35368
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre George, Anthe
9 (RLIN) 42398
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Álvarez, Patricia
9 (RLIN) 25173
245 00 - TITULO
Título Isolation of size exclusion chromatography elution-fractions of coal and petroleum-derived samples and analysis by laser desorption mass spectrometry
260 ## - PUBLICACION, DISTRIBUCION, ETC
Fecha de publicación, distribución, etc. nov./dic. 2009
270 ## - FECHA DE CARGA
Fecha de carga 09/06/2010 ; 09/06/2010
300 ## - DESCRIPCION FISICA
Otra extensión 12 p. ; 6003-6014
520 ## - RESUMEN, ETC
Resumen Transcripción del resumen del autor. High-mass species in a coal- and a petroleum-derived sample were investigated by LD-MS of eluent fractions collected from SEC. Results were compared with polymer-based calibrations of SEC elution times. It was observed that polymer- and PAH-based calibrations provide good mass estimates for material eluting in the resolved (later eluting) part of SEC chromatograms. At elution times shorter that 15 min (i.e., in the "excluded" region) there was significant deviation from the PS calibration for both the coal tar pitch and the petroleum-derived samples. In all cases, however, material eluting early during SEC was observed by LD-MS to have higher average masses compared to later-eluting material. The data appears conclusive. An upper limit to the detection of high-mass material by LD-MS appears to have been reached. When comparing mass estimates by LD-MS of SEC elution-fractions of material from the coal tar pitch and petroleum asphaltene, similar molecular mass ranges were found for fractions collected at similar elution times. This provides significant confirmation for the suitability of SEC as a technique for estimating molecular masses of complex hydrocarbon mixtures. The analytical approach presented in this paper provides a valid and useful basis for exploring relationships between molecular size, molecular mass, and structure for complex coal and petroleum-derived materials.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 6
773 0# - CORRECCIÓN
Título Energy & fuels
Partes relacionadas 23
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
Fuente de clasificación Dewey Decimal Classification
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200045699   200045699 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales