NEW THERMAL CONDUCTIVITY MICROSENSOR TO MEASURE THE METHANE NUMBER OF NATURAL GAS (Record no. 170517)

MARC details
000 -LEADER
fixed length control field 02257nam a2200193 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s xxu
245 00 - TITULO
Título NEW THERMAL CONDUCTIVITY MICROSENSOR TO MEASURE THE METHANE NUMBER OF NATURAL GAS
270 ## - FECHA DE CARGA
Fecha de carga 02/09/2025 ; 2009-09-30
300 ## - DESCRIPCION FISICA
Otra extensión 12 p.
500 ## - NOTAS
Nota general Consulte por la disponibilidad de este documento
520 ## - RESUMEN, ETC
Resumen As a result of the liberalization of the gas market, more important and frequent fluctuations of the natural gas composition are expected. Owing to this fact, the on-site control of the gas properties will become necessary for end-users. Methane Number is the parameter used to quantify knocking tendency of a gas, parameter especially relevant when natural gas is used as engines fuel. The present paper describes a measurement method to determine the Methane Number of natural gas as well as the microdevices developed to carry out these measurements. The method is based on the measurement of the gas Thermal Conductivity and the existing correlation between this parameter and the Methane Number of natural gas. The developed microsensors are ascribed to Microsystems Technology. They integrate two platinum thermoresistors: a reference one to measure the gas temperature and a sensing one to measure its thermal conductivity. In order to reduce thermal losses to the silicon substrate two different approaches are proposed: a) microbridges to locate the thermoresistors and b) oxidized porous-silicon isolation. In the range of natural gas compositions considered (60-100MN), applying a 50mA constant current to the sensing thermoresistor, obtained sensitivity is 0.95mV/1MN. Thermal stability and mechanical behaviour of both approaches are compared. Furthermore, the microdevices are mounted in a gas line in order to test them in field. Additional tests are still required but it can be concluded that the developed microsensors are a valid alternative to measure in situ the Methane Number of natural gas.
773 ## - CORRECCIÓN
Partes relacionadas
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Congresos (trabajos presentados)
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Gutierrez, A. M.
9 (RLIN) 22208
110 2# - RESPONSABLE INSTITUCIONAL
Responsable Institucional International Gas Union, IGU
9 (RLIN) 13105
111 2# - AUTORIDAD DE CONGRESO
Nombre de congreso World Gas Conference (23rd. : 2006 jun 5-9 : Amsterdam, The Netherlands)
9 (RLIN) 39854
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200045357   200045357 05/03/2026 Congresos (trabajos presentados)


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales