Visualization of biomass pyrolysis and temperature imaging in a heated-grid reactor (Record no. 170229)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02037nab a2200193 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2009 xxu |
| 245 00 - TITULO | |
| Título | Visualization of biomass pyrolysis and temperature imaging in a heated-grid reactor |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | ene. 2009 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 30/07/2009 ; 30/07/2009 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 15 p. ; 993-1006 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resúmen publicado por el autor: The main advantage of a heated-grid reactor for studying pyrolysis kinetics of solid fuel samples is that high heating rates of up to 1000 K/s can be obtained. However, one of the concerns is whether the temperature distribution over the grid material is uniform and whether the presence of a thermocouple welded to the grid causes any measurement errors. Biomass samples were placed on the heated-grid reactor, and the volatiles, emitted in the biomass pyrolysis process as hot gas plumes, were imaged with an infrared camera with a high framing speed. The temporal resolved infrared images indicate that the pyrolysis process does not take place at the same rate everywhere on the grid. Two-dimensional temperature images of a heated grid made of stainless steel were recorded using the method of laser-induced thermometry with thermographic phosphors. As expected from a heat-transfer model, measured temperatures were found to be significantly higher than temperatures indicated by a thermocouple welded to the bottom of the grid. It was also observed that there is a large temperature gradient between the two electrodes on which the grid is connected. It is shown that replacing a wire mesh by a foil as a grid material may lead to more homogeneous temperature distribution. The paper recommends additional research to demonstrate the suitability of the heated-grid reactor for carrying out accurate measurements. |
| 773 0# - CORRECCIÓN | |
| Título | Energy & fuels |
| Partes relacionadas | 23 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Prins, M.J. |
| 9 (RLIN) | 41663 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Lindén, J. |
| 9 (RLIN) | 41664 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Li, Z.S. |
| 9 (RLIN) | 41665 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 05/03/2026 | 200045057 | 200045057 | 05/03/2026 | Artículo de Revista |