Friction pressure correlations for turbulent flow of drag reducing polymer solutions in straight and coiled tubing (Record no. 169719)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02935nab a2200181 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2009 xxu |
| 245 00 - TITULO | |
| Título | Friction pressure correlations for turbulent flow of drag reducing polymer solutions in straight and coiled tubing |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Lugar de publicación, distribución, etc. | |
| Nombre de publicador, distribuidor, etc. | |
| Fecha de publicación, distribución, etc. | abril. 2009 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 2009-05-11 ; 2009-05-11 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 15 p. ; 147-161 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Resumen publicado por el autor: Available online 11 January 2009. Abstract Accurate determination of friction pressure losses of dilute drag reducing polymer solutions remains to be a challenge in many practical applications. These include a wide variety of hydraulic operations performed on a daily basis in the oil and gas industry. Most drilling, completions, and stimulation jobs require pumping fluids at high flow rates, which in turn generates high frictional pressure losses, enhanced by the use of small diameter tubing or coiled tubing. Curvature in this latter is believed to generate secondary flows and thus extra flow resistance. Therefore, good drag reduction characteristics of fluids are desirable. In this study, energy dissipation by eddies in turbulent flow of viscoelastic fluids is assumed to be the mechanism causing drag reduction. Various concentrations of Nalco ASP-700 and Nalco ASP-820 dilute polymer solutions are tested at ambient temperature in laboratory-scale and full-scale flow loops installed with straight and coiled tubing sections exhibiting different values of diameter, curvature ratio and pipe roughness. In addition, flow tests are conducted at 100 °F and 130 °F using the laboratory-scale flow loop. Effects of concentration, temperature, curvature ratio, and pipe roughness on drag reduction are discussed in light of Fanning friction factor versus solvent Reynolds number plots. Results show that drag reduction in coiled tubing is lower than in straight tubing. As curvature ratio increases, drag reduction decreases. The effect of increasing temperature is to decrease drag reduction in straight tubing and increase it in coiled tubing. In turn, the effect of increasing pipe roughness is to slightly decrease drag reduction in straight tubing up to a certain Reynolds number value and then it starts to increase. For coiled tubing, the effect of increasing pipe roughness is to decrease drag reduction. In this study, generalized correlations for the prediction of drag reduction in dilute polymer solutions flowing in straight and coiled tubing are developed on the basis of the energy dissipation of eddies in turbulent flow field and a shear rate dependent relaxation time. In addition, correlations are validated using experimental data for a low concentration guar fluid flowing through full-scale flow loop |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 3-4 |
| 773 0# - CORRECCIÓN | |
| Título | Journal of Petroleum Science & Engineering |
| Partes relacionadas | 65 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Gallego, Felipe |
| 9 (RLIN) | 41121 |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 05/03/2026 | 200044528 | 200044528 | 05/03/2026 | Artículo de Revista |