Underground gas storage in a partially depleted gas reservoir (Record no. 169119)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02536nab a2200217 4500 |
| 008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL | |
| Campo de control de longitud fija | 260224s2008 xxu |
| 245 00 - TITULO | |
| Título | Underground gas storage in a partially depleted gas reservoir |
| 260 ## - PUBLICACION, DISTRIBUCION, ETC | |
| Fecha de publicación, distribución, etc. | nov./dic. 2008 |
| 270 ## - FECHA DE CARGA | |
| Fecha de carga | 15/05/2009 ; 24/02/2009 |
| 300 ## - DESCRIPCION FISICA | |
| Otra extensión | 12 p. ; 691-703 |
| 520 ## - RESUMEN, ETC | |
| Resumen | Transcripción del resúmen publicado por el autor: In this work, underground gas storage (UGS) was studied on a partially depleted gas reservoir through compositional simulation. Prediction of reservoir fluid phase behavior and history matching was done by utilizing detailed reservoir information. The performance of UGS with different scenarios of reservoir depletion, gas injection, and aquifer strength was analyzed. The injection capacity and deliverability of reservoir was set to 350 MMSCF/D (6 months) and 420 MMSCF/D (5 months), respectively. Based on different scenarios and the anticipated target rate, the optimum pressure for converting this reservoir to UGS was found to be about 1600 psia. Also, it was found that if the reservoir is depleted to a lower pressure, it contains insufficient base gas reserve and may not meet the target withdrawal rate. Results showed that this problem can be overcome by injecting higher volume of gas in the first cycle. Furthermore, it was shown that an active aquifer can lead to irreversible reservoir shrinkage, increase in water-gas ratio, and pressure rise in reservoir. Another source of pressure rise during the UGS operations is the difference between z-factors of injected and reservoir fluids. It was found that injecting lean gas with high z-factor into a reservoir containing fluid of lower z-factor results in pressure rise at the end of each cycle. At successive cycles, composition of reservoir fluid approaches that of the injected gas because of continual mixing. Theoretically, composition of reservoir fluid will be near the injected fluid after infinite cycles, provided complete mixing occurs in reservoir. Under these conditions, difference between z-factors of injected and reservoir fluids become smaller, and reservoir pressure stabilizes. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 6 |
| 773 0# - CORRECCIÓN | |
| Descripción física | 63 |
| Título | Oil and Gas Science and Technology |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Azin, R. |
| 9 (RLIN) | 40376 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Nasiri, A. |
| 9 (RLIN) | 40377 |
| 100 1# - RESPONSABLE PERSONAL | |
| Apellido, Nombre | Entezari, A. Jodeyri |
| 9 (RLIN) | 40378 |
| 856 ## - LINK | |
| Link | <a href="http://ogst.ifp.fr/index.php?option=article&access=standard&Itemid=129&url=/articles/ogst/pdf/2008/06/ogst07094.pdf">http://ogst.ifp.fr/index.php?option=article&access=standard&Itemid=129&url=/articles/ogst/pdf/2008/06/ogst07094.pdf</a> |