Electrochemical corrosion potential of carbon steel feeder pipes in a Canadian deuterium urabiun reactor generating station under return-to-service conditions (Record no. 168891)

MARC details
000 -LEADER
fixed length control field 02006nab a2200193 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s2009 xxu
245 00 - TITULO
Título Electrochemical corrosion potential of carbon steel feeder pipes in a Canadian deuterium urabiun reactor generating station under return-to-service conditions
260 ## - PUBLICACION, DISTRIBUCION, ETC
Lugar de publicación, distribución, etc.
Nombre de publicador, distribuidor, etc.
Fecha de publicación, distribución, etc. ene. 2009
270 ## - FECHA DE CARGA
Fecha de carga 21/01/2009 ; 16/01/2009
300 ## - DESCRIPCION FISICA
Otra extensión 11 p. ; 49-60
520 ## - RESUMEN, ETC
Resumen One of the principle factors affecting the stress corrosion cracking (SCC) of a susceptible metal is its corrosion potential. A number of instances of cracking on th outlet feeder pipes of the primary heat transport (PHT) system at the Point Lepreau Generating Station ([PLGS] Lepreau, NB, Canada), a heavy water reactor, have been observed and are likely associated with either SCC or hydrogen-enhanced creep cracking. The potential of the outlet feeder pipes was inferred from representative electrochemical corrosion potential probes, pre-filmed in the laboratory, and exposed to a PHT coolant during a maintenance outage and reactor restart. Laboratory tests of the probes were also conducted over the full range of plant operating temperatures to provide a reasonable estimate of return-to-service conditions. The laboratory results were generally in good agreement with the PLGS data under deoxygenated and oxygenated conditions or temperatures of less than 80°C. Neither the removal of dissolved oxygen at low temperatures at PLGS, after a maintenance outage, nor in the laboratory simulation was efficient to reduce the potential of the carbon steel below the region of susceptibility to SCC. It was only with the increase in temperature toward normal operating conditions that the potential decreased to that expected for the typical reducing conditions of the PHT coolant.
581 ## - ESTADO DE COLECCIÓN
Estado de colección 1
773 0# - CORRECCIÓN
Título Corrosion
Partes relacionadas 65
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Artículo de Revista
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Scott, A.N.
9 (RLIN) 40175
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Mawhinney, W.R.
9 (RLIN) 40176
Holdings
Biblioteca propietaria Biblioteca actual Fecha de adquisición Inventario Total de préstamos Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni 05/03/2026 200043679   200043679 05/03/2026 Artículo de Revista


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales