Close to pipeline accident (Record no. 149696)

MARC details
000 -LEADER
fixed length control field 02112nmc a2200217 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s xxu
082 ## - CLASIFICACIÓN DEWEY
Número de clasificación CD I249 1 0013788
245 00 - TITULO
Título Close to pipeline accident
270 ## - FECHA DE CARGA
Fecha de carga 12/09/06 ; 22/07/2003
300 ## - DESCRIPCION FISICA
Otra extensión 5 p.
500 ## - NOTAS
Nota general Disponible en CD en formato PDF
520 ## - RESUMEN, ETC
Resumen Transcripción del abstract original del autor: This paper is a true story how gas transmission company decided after pipeline risk assessement work to inspect an old high pressure gas transmission pipeline The original design of the pipeline that goes through high populated areas was non-pigable. Modification of the pipeline; new valve stations with pig traps were designed and installed. Next step was the cleaning and calibration of the old dirty pipeline. A lot of dust and debris was pushed out from the pipeline. And finally the inspection pig run, how the inspection tool goes in tight bends and over river grossing within bridge. Results from inspection run. Serious defects were found just at last moment before failure. Main reason for defect was bad design combined with small coating failure and AC-currents from nearby bridge with electrical power cables. The gas pipeline goes in the same bridge over river. Also very interesting is that within that certain pipe spool defect was located, there were no cathodic protection. During construction some money was saved so that insulating joints were installed underground instead above ground installation, so the spool next to bridge was left without CP. It was also one reason for defect. To continue safe gas transmission, more traps will be installed to existing pipelines, and they will be inspected. All new pipelines will be built pigable and baseline surveys will be made to get fingerprints after construction.
773 ## - CORRECCIÓN
Partes relacionadas
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Congresos (trabajos presentados)
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Korpela, Arto
9 (RLIN) 22331
110 2# - RESPONSABLE INSTITUCIONAL
Responsable Institucional International Gas Union, IGU
9 (RLIN) 13105
111 2# - AUTORIDAD DE CONGRESO
Nombre de congreso World Gas Conference (22nd. : 2003 jun 1-5 : Tokyo)
9 (RLIN) 22029
710 2# - OTRA AUTORIDAD CORPORATIVA
Nombre Institucional International Gas Union, IGU
9 (RLIN) 13105
Holdings
Biblioteca propietaria Biblioteca actual Ubicación Fecha de adquisición Inventario Total de préstamos Signatura topográfica Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 04/03/2026 200025690   CD I249 1 0013788 200025690 04/03/2026 Archivo electrónico


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales