Assessment of the condition of high-pressure gas pipelines as a basis for maintenance (Record no. 149618)

MARC details
000 -LEADER
fixed length control field 01913nmc a2200205 4500
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA - INFORMACIÓN GENERAL
Campo de control de longitud fija 260224s xxu
082 ## - CLASIFICACIÓN DEWEY
Número de clasificación CD I249 1 0013788
100 1# - RESPONSABLE PERSONAL
Apellido, Nombre Hoffmann, Ulrich
9 (RLIN) 22226
110 2# - RESPONSABLE INSTITUCIONAL
Responsable Institucional International Gas Union, IGU
9 (RLIN) 13105
111 2# - AUTORIDAD DE CONGRESO
Nombre de congreso World Gas Conference (22nd. : 2003 jun 1-5 : Tokyo)
9 (RLIN) 22029
245 00 - TITULO
Título Assessment of the condition of high-pressure gas pipelines as a basis for maintenance
Subtítulo Integrated approach to reliability assessment at VNG - Verbundnetz Gas Aktiengesellschaft
270 ## - FECHA DE CARGA
Fecha de carga 12/09/06 ; 22/07/2003
300 ## - DESCRIPCION FISICA
Otra extensión 13 p.
500 ## - NOTAS
Nota general Disponible en CD en formato PDF
520 ## - RESUMEN, ETC
Resumen Transcripción del abstract original del autor: Over the last few years, Verbundnetz Gas Aktiengesellschaft (VNG) developed an integrated system for the technical condition analysis (TCA) of high-pressure gas pipelines which represents a major step toward the predictive maintenance of high-pressure gas lines. Specific evaluation tools such as the KaRo program for assessing pigging results and the program for assessing defects in old welds incorporate the latest scientific advances. TZA uses probabilistic evaluation principles for assessing rehabilitation requirements in VNG's old lines. The approach has fundamentally changed VNG's strategies for maintaining high-pressure gas lines, meaning that - rehabilitation is limited to repairing acute defects which have been accurately assessed and located, - other defects are classified into a phased rehabilitation program based on reserve service life, - costs are reduced to the level required for reliable operation and supply, - planning confidence exists in the preparation/implementation of proposed steps, and - the reliability and technical integrity of VNG's network can be verified.
710 2# - OTRA AUTORIDAD CORPORATIVA
Nombre Institucional International Gas Union, IGU
9 (RLIN) 13105
942 ## - DESC. DE MATERIAL
Tipo de item KOHA Congresos (trabajos presentados)
Holdings
Biblioteca propietaria Biblioteca actual Ubicación Fecha de adquisición Inventario Total de préstamos Signatura topográfica Inventario Fecha de carga Tipo de item KOHA
Biblioteca Alejandro Angel Bulgheroni Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 04/03/2026 200025611   CD I249 1 0013788 200025611 04/03/2026 Archivo electrónico


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales