Performance of different temperature sensors in standard fire resistance test furnaces

Sultan, Mohamed A.

Performance of different temperature sensors in standard fire resistance test furnaces - oct. 2010 - 28 p. ; 853-881

Transcripción del resumen del autor. Defining a methodology for measuring temperature in fire resistance furnaces is a challenge. This paper presents and discusses the performance of six different types of temperature sensors in wall and floor fire resistance furnaces namely: the ASTM E119 shielded thermocouples, ISO 834 plate thermometers, directional flame thermometers, bare-bead thermocouples, Inconel grounded and ungrounded sheathed thermocouples. The Inconel grounded and ungrounded sheathed thermocouples provided comparable results to those of the bear-bead thermocouples and are most suitable when a fast response time is desirable. Because of the fast response time and good durability, grounded and ungrounded junction thermocouples are well-suited for use in controlling the temperature in fire resistance standard test furnaces. The predicted and measured incident heat flux in furnaces controlled by either the bare-bead or grounded and ungrounded sheathed thermocouples are in good agreement.

4


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales