MIC failure of type 316L seawater pipeline

Abraham, Geogy J. Kain, V. Dey, G.K.

MIC failure of type 316L seawater pipeline - ene. 2009 - 6 p. ; 64-69

Transcripción del resumen del autor. Type 316L stainless steel (SS) (UNS S31600) pipeline carrying seawater suffered pitting and leakage within a few years of installation. Visual examination revealed penetrations and shallow pits. Electron probe microanalysis results indicated a decrease in chromium concentration withing the pit and in the iron concentration at the pit periphery. Microbial investigation confirmed the presence of sulfate- reducing bacteria and chromium-, manganese-, and iron-oxidizing bacteria