A guide to understanding reference electrode readings

Park, Robert M. Miller, M.C. Florida, Sebastian

A guide to understanding reference electrode readings - sep. 2009 - 7 p. ; 33-39

Transcripción del resumen del autor. Reference electrodes are essential to evaluate corrosion and cathodic protection on buried and submerged structures. This article discusses the nature of structure-to-electrolyte readings employing copperlcopper sulfate (Cu/CuSO) electrodes (CSEs) and various other "acceptable" reference electrode types. A universal formula is presented that allow readings taken with non-CSE reference electrodes to be adjusted to the CSE potential.