Using industrial computerized tomography for corrosion investigation
Using industrial computerized tomography for corrosion investigation
- dic. 2007
- 3 p. ; 60-62
Industrial computerized tomography (ICT) was used to investigate the corrosion failure of a chlorine condenser tube, shell, and welding. The ICT analysis indicated that corrosion was most serious where the tube and shell were welded together. This work also showed that ICT can be a valuable tool in corrosion analysis because it can detect gaps or interstices, and quantify their size, shape, and position.
12
Tomografía computada
Investigación y Desarrollo
Industrial computerized tomography (ICT) was used to investigate the corrosion failure of a chlorine condenser tube, shell, and welding. The ICT analysis indicated that corrosion was most serious where the tube and shell were welded together. This work also showed that ICT can be a valuable tool in corrosion analysis because it can detect gaps or interstices, and quantify their size, shape, and position.