Design alternatives for sweetening LPG's and liquid hydrocarbons with amines
Fleming, K.B. Spears, M.L. Bullin, Jerry A.
Design alternatives for sweetening LPG's and liquid hydrocarbons with amines - Texas Bryan Research & Engineering 2001
Artículo publicado en la página web de Bryan Research & Engineering (http://www.bre.com) donde se pueden consultar otros artículos sobre temas relacionados. ; Página web visitada en enero de 2004. ; Navegadores de Internet
Transcripción del resumen presentado por el autor, en inglés: Amine solutions are often used to treat LPG streams that contain acid gases. In this work, the selection of an amine and the method of contacting the amine with a 50gpm [189 lpm] LPG stream containing 7.7 mol% as CO2 are evaluated. A packed contactor is compared to a static mixer and MEA, DEA, and MDEA are compared as potential solvents. A static mixer using 70 gpm [265 lpm] of 25 wt.% DEA is chosen for the final design. The operating data reveal 0.10 mol% CO2 in the sweet LPG compared to the design value of 0.16 mol%.
Tratamiento de gases licuados
GLP. Gas Licuado de Petróleo
Tratamiento de gas con aminas
Absorción
Desulfurización
Endulzamiento
Diagrama de flujos
Condiciones operativas
Design alternatives for sweetening LPG's and liquid hydrocarbons with amines - Texas Bryan Research & Engineering 2001
Artículo publicado en la página web de Bryan Research & Engineering (http://www.bre.com) donde se pueden consultar otros artículos sobre temas relacionados. ; Página web visitada en enero de 2004. ; Navegadores de Internet
Transcripción del resumen presentado por el autor, en inglés: Amine solutions are often used to treat LPG streams that contain acid gases. In this work, the selection of an amine and the method of contacting the amine with a 50gpm [189 lpm] LPG stream containing 7.7 mol% as CO2 are evaluated. A packed contactor is compared to a static mixer and MEA, DEA, and MDEA are compared as potential solvents. A static mixer using 70 gpm [265 lpm] of 25 wt.% DEA is chosen for the final design. The operating data reveal 0.10 mol% CO2 in the sweet LPG compared to the design value of 0.16 mol%.
Tratamiento de gases licuados
GLP. Gas Licuado de Petróleo
Tratamiento de gas con aminas
Absorción
Desulfurización
Endulzamiento
Diagrama de flujos
Condiciones operativas