The introduction report of damage monitoring system for trunkline

Miura, Satoru

The introduction report of damage monitoring system for trunkline - 4 p.

Disponible en CD en formato PDF

Transcripción del abstract original del autor: High-pressure gas pipeline coating can be damaged by various causes. A damage monitoring system automatically detects and locates such damage and immediately calls a control center. For pipelines consisting of steel pipe coated with polyethylene or similar highinsulation material and cathodically protected using a single external power supply unit, coating damage caused by interference from machinery operated for earthworks of other companies can be detected by changes in the cathodic protection current. Osaka Gas has been using this system in some of its gas pipelines as one measure for monitoring interference caused by earthworks of other companies. However, in areas crowded with stray currents, such as current leaking from railway tracks and cathodic protection current for other underground structures, the system has great difficulty detecting coating damage due to electric noise disturbance. To cope with this problem, we studied the possibility of using an alternate current as a signal current exclusively for damage detection, and have successfully developed a new damage monitoring system that features high noise immunity and greatly improved detection accuracy. The work of introducing this new system to the Kinki Western Trunk Line II (4 sections, total length of 158 km) and the Kinki Western Trunk Line III (total length of 73 km) commenced in 1998 and was completed in May 2002.

CD I249 1 0013788


Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales