Image from Google Jackets

Quantifying Heat Requirements for SAGD Startup Phase: Steam Injection, Electrical Heating

By: Language: Inglés Publication details: mar. 2013Description: 5 p. ; 89-94 In: Journal of Canadian Petroleum Technology 52Summary: Transcripción del resumen del autor. A proper and effective startup of the steam-assisted-gravity-drainage (SAGD) well pairs, where both horizontal wells inject steam, is a key parameter to SAGD performance. In the past, a number of investigations have been conducted on the optimum startup strategy and operational procedures; however, fewer studies have modelled the heat requirements of the process. This study proposes an effective practical method that correlates the heat flux inside the horizontal wellbore with the temperature outside the wellbore wall. A transient conductive-heat-transfer equation in a cylindrical coordinate system is adopted for two different startup strategies: (a) variable heat flux (steam circulation in the well pair) to maintain a constant desired temperature at the wellbore wall and (b) constant heat flux (electrical heating of the well pair) to gradually increase temperature and finally reach a desired temperature on the wellbore wall. A novel and simple mathematical technique is presented for each startup approach to evaluate the instantaneous and cumulative heat requirements to keep the wellbore hot. Excellent agreements between the results of the proposed techniques and outputs of a commercial reservoir simulator are demonstrated. Accurate quantitative evaluation of heat requirements for the startup phase of SAGD enables optimum planning for steam requirements and practical design of any other heat sources employed in the process.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200059887

Transcripción del resumen del autor. A proper and effective startup of the steam-assisted-gravity-drainage (SAGD) well pairs, where both horizontal wells inject steam, is a key parameter to SAGD performance. In the past, a number of investigations have been conducted on the optimum startup strategy and operational procedures; however, fewer studies have modelled the heat requirements of the process. This study proposes an effective practical method that correlates the heat flux inside the horizontal wellbore with the temperature outside the wellbore wall. A transient conductive-heat-transfer equation in a cylindrical coordinate system is adopted for two different startup strategies: (a) variable heat flux (steam circulation in the well pair) to maintain a constant desired temperature at the wellbore wall and (b) constant heat flux (electrical heating of the well pair) to gradually increase temperature and finally reach a desired temperature on the wellbore wall. A novel and simple mathematical technique is presented for each startup approach to evaluate the instantaneous and cumulative heat requirements to keep the wellbore hot. Excellent agreements between the results of the proposed techniques and outputs of a commercial reservoir simulator are demonstrated. Accurate quantitative evaluation of heat requirements for the startup phase of SAGD enables optimum planning for steam requirements and practical design of any other heat sources employed in the process.

2



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales