Image from Google Jackets

Survey results of combustible contents and floor areas in Canadian multi-family dwellings

By: Publication details: oct. 2011Description: 19 p. ; 1121 - 1140 In: Fire Technology 47Summary: Transcripción del resumen del autor This paper presents an investigation on the fire performance of wood–steel–wood timber connections with slotted-in steel plates. In the first part, a three-dimensional thermal model was employed that uses the finite element method to analyze heat transfer within timber connections exposed to the standard fire. The temperature-related properties were obtained from the literature and imported into the thermal model. A validation of the proposed thermal model was achieved by comparing predicted temperatures with experimental results. In the next phase, a reduction in the embedding strength method was adopted to estimate the load-carrying capacity of connections in fire. Based on the temperature profiles within the connection calculated by the thermal model, the reduction of the embedding strength was determined and used to calculate the load capacity at elevated temperatures. Furthermore, a formula was proposed to evaluate the fire resistance rating of timber connections and compared with the results of fire resistance tests. The parameters considered included the load level, fastener diameter and wood member thickness.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200059162

Transcripción del resumen del autor This paper presents an investigation on the fire performance of wood–steel–wood timber connections with slotted-in steel plates. In the first part, a three-dimensional thermal model was employed that uses the finite element method to analyze heat transfer within timber connections exposed to the standard fire. The temperature-related properties were obtained from the literature and imported into the thermal model. A validation of the proposed thermal model was achieved by comparing predicted temperatures with experimental results. In the next phase, a reduction in the embedding strength method was adopted to estimate the load-carrying capacity of connections in fire. Based on the temperature profiles within the connection calculated by the thermal model, the reduction of the embedding strength was determined and used to calculate the load capacity at elevated temperatures. Furthermore, a formula was proposed to evaluate the fire resistance rating of timber connections and compared with the results of fire resistance tests. The parameters considered included the load level, fastener diameter and wood member thickness.

4



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales