Managing pipeline integrity by mitigating alternating current interference

By: Publication details: mayo 2010Description: 6 p. ; 32-37 In: Materials Performance 49Summary: Transcripción del resumen del autor. The main concerns in sharing a corridor between pipelines and power transmission lines are personnel safety, corrosion, and coating damage. High-voltage, alternating current-induced corrosion is a significant threat to pipeline integrity. This article describes a simultaion software that models both resistive and inductive interference and presents practical results of simulations on two different configurations
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200047439

Transcripción del resumen del autor. The main concerns in sharing a corridor between pipelines and power transmission lines are personnel safety, corrosion, and coating damage. High-voltage, alternating current-induced corrosion is a significant threat to pipeline integrity. This article describes a simultaion software that models both resistive and inductive interference and presents practical results of simulations on two different configurations