Measuring water well corrosion rate in situ using LPR technique

By: Publication details: feb. 2011Description: 2 p. ; 48-50 In: Materials Performance 50Summary: Transcripción del resumen del autor. Linear polarization resistance (LPR) measurements were used to monitor water well corrosion in situ. Four Carbon steels and two stainless steels were evaluated at a depth of 150m. Test indicated that the LPR method is a dependable and faster alternative to the traditional coupon technique
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200051486

Transcripción del resumen del autor. Linear polarization resistance (LPR) measurements were used to monitor water well corrosion in situ. Four Carbon steels and two stainless steels were evaluated at a depth of 150m. Test indicated that the LPR method is a dependable and faster alternative to the traditional coupon technique