Internal corrosion from galvanic anode cathodic interference Phorgotten phenomena

By: Publication details: dic. 2010Description: 4 p. ; 34-37 In: Materials Performance 49Summary: Transcripción del resumen del autor. Cathodic interference is a common problem caused by the effect of stray current on one structure from the cathodic protection (CP) system on another structure. Although this phenomenon is nearly always associated with impresed current CP, it can occur with galvanic anode CP systems. This article desccribes a case study of a situation where galvanic CP caused cathodic interference in an unusual way
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200050294

Transcripción del resumen del autor. Cathodic interference is a common problem caused by the effect of stray current on one structure from the cathodic protection (CP) system on another structure. Although this phenomenon is nearly always associated with impresed current CP, it can occur with galvanic anode CP systems. This article desccribes a case study of a situation where galvanic CP caused cathodic interference in an unusual way