Image from Google Jackets

Analysis of pressure relief valve proof test data

By: Publication details: mar. 2009Description: 6 p. ; 24-29 In: Process safety progress 28Summary: This article reports on our statistical analysis of pressure relief valve (PRV) proof test data for the failure mode, fail-to-open, i.e., the PRV remains closed when actual pressure reaches or exceeds 150% of set pressure. Three data sets, from two Fortune 500 operating companies, which met the intent of the quality assurance of proof test data as documented by the Center for Chemical Process Safety Process Equipment Reliability Database (CCPS PERD)[Note 1] initiative, were analyzed. Although the original intent of our analysis focused solely on estimating the failure rate during the useful life[Note 2] of the equipment, it became apparent that the probability of failure on initial installation or reinstallation after proof test, and the need to address what constituted end of useful life were very significant.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200044193

This article reports on our statistical analysis of pressure relief valve (PRV) proof test data for the failure mode, fail-to-open, i.e., the PRV remains closed when actual pressure reaches or exceeds 150% of set pressure. Three data sets, from two Fortune 500 operating companies, which met the intent of the quality assurance of proof test data as documented by the Center for Chemical Process Safety Process Equipment Reliability Database (CCPS PERD)[Note 1] initiative, were analyzed. Although the original intent of our analysis focused solely on estimating the failure rate during the useful life[Note 2] of the equipment, it became apparent that the probability of failure on initial installation or reinstallation after proof test, and the need to address what constituted end of useful life were very significant.

1



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales